PPC322BE HIEE300900R0001
ABB
T/T
1 year
Availability: | |
---|---|
Quantity: | |
The ABB PPC322BE HIEE300900R0001 is a processing unit from ABB's AC 800M controller series. It is a discontinued product, but you can still find some information and suppliers online. Here's what I found:
Product ID: HIEE300900R0001
Description: PP C322 BE01 PSR-2 processor + fieldbus
Country of Origin: Switzerland
Dimensions: 20.3 cm x 7.6 cm x 25.4 cm
Weight: 1.5kg
Our Sell Brand
Allen-Bradley ( 1746-IB32, 1747-L533, 1756-ENBT, 1756-L61, 1769-OF4, 1771-IBN, 1785-L40B )
Bently Nevada ( 3500/94, 3500/53, 3500/22M, 3500/42M, 330180-90-00 )
Honeywell ( TK-PRS021, TC-FPDXX2, CC-TCNT01, 8C-PAIH51, 51309355-001, 10006/2/1 )
ABB ( 07KT97 WT97, AI835, CI854AK01, DSQC639, DO810, PM861AK01, SNAT603 )
Triconex ( 3625, 3503E, 3008, TCM 4353, 4351B, 4409)
GE Fanuc(IS200VVIBH1CAB DS200LDCCH1AGA IS220PAICH2A IC200MDL640K)
Yokogawa(CP451-10,SSB401-13,PW482-10,SB401-10,MX3*D,ST2*D)
Invensys( 4329, 3805E, 3503E,3721,3636T,DO3401,3625)
Siemens( 6ES7332-5HD01-0AB0, 6ES7414-4HJ04-0AB0, 6ES7417-4HT14-0AB0)
Foxboro ( FBM205, FBM211, FBM202, FBM217, FCM10E, P0971WV, FBMSVH)
ICS Triplex ( T8310, T8431, T8461, T8451, T8110B, T8403, T3481)
More Products
T8831 | F1101 | F31X139APMALG2FR01 | NCNI P0972PP |
T8173 | F2201 | HE693THM884 | P0926HM |
T9193 | F3113A | IC693MDL640 | FBM218 P0922VW |
T9191 | F3221 | IC697PCM711 | CP40 |
T8232C | F3236 | VCIB-16A | P0926HT |
T8086 | F3237 | IC697MEM715B | FBM204 P0914SY |
T8433C | F3322 | IC697CPU772 | FCM100ET P0926GS |
T8830C | F3330 | IC3000CS200M | AD916AE |
T8891C | F3331 | DS200RTBAG3AEB | P0926JC |
T8850C | F3334 | DS200TBQCG1ABB | ZCP270 P0926CP-0E |
T8451C | F3417A | 531X305NTBAPG1 | P0961BS-OC |
Description
A circuit-breaker must control and protect, in case of faults or malfunctioning, the connected elements of a plant. In order to perform this function, after detection of an anomalous condition, the release intervenes in a definite time by opening the interrupting part. The protection releases fitted with ABB SACE moulded-case and air circuitbreakers can control and protect any plant, from the simplest ones to those with particular requirements, thanks to their wide setting possibilities of both thresholds and tripping times. Among the devices sensitive to overcurrents, the following can be considered: • thermomagnetic releases and magnetic only releases; • microprocessor-based releases; • residual current devices. The choice and adjusting of protection releases are based both on the requirements of the part of plant to be protected, as well as on the coordination with other devices; in general, discriminating factors for the selection are the required threshold, time and curve characteristic.
The ABB PPC322BE HIEE300900R0001 is a processing unit from ABB's AC 800M controller series. It is a discontinued product, but you can still find some information and suppliers online. Here's what I found:
Product ID: HIEE300900R0001
Description: PP C322 BE01 PSR-2 processor + fieldbus
Country of Origin: Switzerland
Dimensions: 20.3 cm x 7.6 cm x 25.4 cm
Weight: 1.5kg
Our Sell Brand
Allen-Bradley ( 1746-IB32, 1747-L533, 1756-ENBT, 1756-L61, 1769-OF4, 1771-IBN, 1785-L40B )
Bently Nevada ( 3500/94, 3500/53, 3500/22M, 3500/42M, 330180-90-00 )
Honeywell ( TK-PRS021, TC-FPDXX2, CC-TCNT01, 8C-PAIH51, 51309355-001, 10006/2/1 )
ABB ( 07KT97 WT97, AI835, CI854AK01, DSQC639, DO810, PM861AK01, SNAT603 )
Triconex ( 3625, 3503E, 3008, TCM 4353, 4351B, 4409)
GE Fanuc(IS200VVIBH1CAB DS200LDCCH1AGA IS220PAICH2A IC200MDL640K)
Yokogawa(CP451-10,SSB401-13,PW482-10,SB401-10,MX3*D,ST2*D)
Invensys( 4329, 3805E, 3503E,3721,3636T,DO3401,3625)
Siemens( 6ES7332-5HD01-0AB0, 6ES7414-4HJ04-0AB0, 6ES7417-4HT14-0AB0)
Foxboro ( FBM205, FBM211, FBM202, FBM217, FCM10E, P0971WV, FBMSVH)
ICS Triplex ( T8310, T8431, T8461, T8451, T8110B, T8403, T3481)
More Products
T8831 | F1101 | F31X139APMALG2FR01 | NCNI P0972PP |
T8173 | F2201 | HE693THM884 | P0926HM |
T9193 | F3113A | IC693MDL640 | FBM218 P0922VW |
T9191 | F3221 | IC697PCM711 | CP40 |
T8232C | F3236 | VCIB-16A | P0926HT |
T8086 | F3237 | IC697MEM715B | FBM204 P0914SY |
T8433C | F3322 | IC697CPU772 | FCM100ET P0926GS |
T8830C | F3330 | IC3000CS200M | AD916AE |
T8891C | F3331 | DS200RTBAG3AEB | P0926JC |
T8850C | F3334 | DS200TBQCG1ABB | ZCP270 P0926CP-0E |
T8451C | F3417A | 531X305NTBAPG1 | P0961BS-OC |
Description
A circuit-breaker must control and protect, in case of faults or malfunctioning, the connected elements of a plant. In order to perform this function, after detection of an anomalous condition, the release intervenes in a definite time by opening the interrupting part. The protection releases fitted with ABB SACE moulded-case and air circuitbreakers can control and protect any plant, from the simplest ones to those with particular requirements, thanks to their wide setting possibilities of both thresholds and tripping times. Among the devices sensitive to overcurrents, the following can be considered: • thermomagnetic releases and magnetic only releases; • microprocessor-based releases; • residual current devices. The choice and adjusting of protection releases are based both on the requirements of the part of plant to be protected, as well as on the coordination with other devices; in general, discriminating factors for the selection are the required threshold, time and curve characteristic.