T8403
ICS Triplex
T/T
1 year
Availability: | |
---|---|
Quantity: | |
The ICS Triplex T8403 is a Trusted TMR 24Vdc Digital Input Module with 40 channels. It is a highly reliable and versatile module that is suitable for a wide range of applications, including safety systems, process control, and automation.
Here are some of the key technical features of the T8403:
Trusted TMR technology: The T8403 uses Triple Modular Redundancy (TMR) technology to ensure the highest level of reliability. This means that each input channel is monitored by three independent sensors, and any errors are automatically detected and corrected.
Comprehensive diagnostics: The T8403 provides comprehensive diagnostics to help you identify and troubleshoot problems. This includes self-test, line monitoring, and on-board Sequence of Events (SOE) reporting.
Opto/galvanic isolation: The T8403 features 2500 V impulse withstand opto/galvanic isolation to protect your system from electrical noise and interference.
Hot-swappable: The T8403 can be hot-swapped on-line, which means that it can be replaced without shutting down your system. This is a valuable feature for applications where downtime is not acceptable.
Here are some of the key technical specifications of the ICS Triplex T8403:
Number of channels: 40
Input voltage: 24Vdc
Input current: 20mA per channel
Input impedance: 10kΩ
Response time: 10ms
Operating temperature range: -40°C to +70°C
Storage temperature range: -55°C to +85°C
Relative humidity: 5% to 95% non-condensing
Vibration: 10g peak, 5 to 15Hz, 2 axes
Shock: 20g peak, 11ms, 3 axes
MTBF: >100 years
Description
The Field Termination Unit (FTU) is the section of the I/O Module that connects all three FIUs to a single field device. The FTU primarily contains passive components necessary for front-end signal conditioning, field signal overvoltage protection, and EMI/RFI filtering. When installed in a Trusted Controller or Expander Chassis, the FTU field connector interconnects to the I/O cable assembly attached at the rear of the Chassis. The SmartSlot link is passed from the HIU to the field connections via the FTU. These signals go directly to the I/O cable assembly and maintain isolation from the I/O signals on the FTU. The SmartSlot link is the intelligent connection between Active and Standby Modules for coordination during Module replacement. The Field Interface Unit (FIU) is the section of the Module that contains the specific circuits necessary to interface to the particular types of field I/O signals. Each Module has three FIUs, one per slice. For the TMR 24 Vdc Digital Input Module, the FIU contains an individual analog to digital (A/D) converter for each of the 40 field inputs. The FIU receives isolated power from the HIU for logic. The FIU provides additional power conditioning for the operational voltages required by the FIU circuitry. An isolated 6.25 Mbit/s serial link connects each FIU to one of the HIU slices.
More Products
FBM242 P0916TA | 3A997693H06 | 6DD2920-0AB1 | AIP171 S2 |
FBM201 P0914SQ | 4A00120H01 | 6DD2920-0AA0 | PW502 S1 |
FCM2F10 P0916TQ | 4A00120H02 | 6GK1140-0AB01 | YNT512D-Q12 |
IPM2-P0904HA | 4A00154H01 | 6GK1100-0AG01 | AAM11 S2 |
P0913UU-OA P0913UTR | 4257A58H08 | 6ES7972-0BB41-0XA0 | AAM21 S2 |
P0914M8B P0913CX-OD | 4257A58H16 | 6ES7407-0KA01-0AA0 | AAM50 S1 |
P0913UG-OA P0913UFA | EX06008 | 6ES7412-2XJ05-0AB0 | AMM32 S3 |
P0913UTC P0913UU-OA | EX06009 | 6ES7412-2XG00-0AB0 | AMM42 S4 |
P0914KJE P0914KP-OA | EX06100 | 6ES7414-2XG03-0AB0 | ADM11 S3 |
P0913UU-OB P0913UTD | EX06101 | 6ES7952-1KM00-0AA0 | SSB401-13 |
The ICS Triplex T8403 is a Trusted TMR 24Vdc Digital Input Module with 40 channels. It is a highly reliable and versatile module that is suitable for a wide range of applications, including safety systems, process control, and automation.
Here are some of the key technical features of the T8403:
Trusted TMR technology: The T8403 uses Triple Modular Redundancy (TMR) technology to ensure the highest level of reliability. This means that each input channel is monitored by three independent sensors, and any errors are automatically detected and corrected.
Comprehensive diagnostics: The T8403 provides comprehensive diagnostics to help you identify and troubleshoot problems. This includes self-test, line monitoring, and on-board Sequence of Events (SOE) reporting.
Opto/galvanic isolation: The T8403 features 2500 V impulse withstand opto/galvanic isolation to protect your system from electrical noise and interference.
Hot-swappable: The T8403 can be hot-swapped on-line, which means that it can be replaced without shutting down your system. This is a valuable feature for applications where downtime is not acceptable.
Here are some of the key technical specifications of the ICS Triplex T8403:
Number of channels: 40
Input voltage: 24Vdc
Input current: 20mA per channel
Input impedance: 10kΩ
Response time: 10ms
Operating temperature range: -40°C to +70°C
Storage temperature range: -55°C to +85°C
Relative humidity: 5% to 95% non-condensing
Vibration: 10g peak, 5 to 15Hz, 2 axes
Shock: 20g peak, 11ms, 3 axes
MTBF: >100 years
Description
The Field Termination Unit (FTU) is the section of the I/O Module that connects all three FIUs to a single field device. The FTU primarily contains passive components necessary for front-end signal conditioning, field signal overvoltage protection, and EMI/RFI filtering. When installed in a Trusted Controller or Expander Chassis, the FTU field connector interconnects to the I/O cable assembly attached at the rear of the Chassis. The SmartSlot link is passed from the HIU to the field connections via the FTU. These signals go directly to the I/O cable assembly and maintain isolation from the I/O signals on the FTU. The SmartSlot link is the intelligent connection between Active and Standby Modules for coordination during Module replacement. The Field Interface Unit (FIU) is the section of the Module that contains the specific circuits necessary to interface to the particular types of field I/O signals. Each Module has three FIUs, one per slice. For the TMR 24 Vdc Digital Input Module, the FIU contains an individual analog to digital (A/D) converter for each of the 40 field inputs. The FIU receives isolated power from the HIU for logic. The FIU provides additional power conditioning for the operational voltages required by the FIU circuitry. An isolated 6.25 Mbit/s serial link connects each FIU to one of the HIU slices.
More Products
FBM242 P0916TA | 3A997693H06 | 6DD2920-0AB1 | AIP171 S2 |
FBM201 P0914SQ | 4A00120H01 | 6DD2920-0AA0 | PW502 S1 |
FCM2F10 P0916TQ | 4A00120H02 | 6GK1140-0AB01 | YNT512D-Q12 |
IPM2-P0904HA | 4A00154H01 | 6GK1100-0AG01 | AAM11 S2 |
P0913UU-OA P0913UTR | 4257A58H08 | 6ES7972-0BB41-0XA0 | AAM21 S2 |
P0914M8B P0913CX-OD | 4257A58H16 | 6ES7407-0KA01-0AA0 | AAM50 S1 |
P0913UG-OA P0913UFA | EX06008 | 6ES7412-2XJ05-0AB0 | AMM32 S3 |
P0913UTC P0913UU-OA | EX06009 | 6ES7412-2XG00-0AB0 | AMM42 S4 |
P0914KJE P0914KP-OA | EX06100 | 6ES7414-2XG03-0AB0 | ADM11 S3 |
P0913UU-OB P0913UTD | EX06101 | 6ES7952-1KM00-0AA0 | SSB401-13 |