Product Description
The modular HIMatrix F60 system is composed of a subrack and various modules inserted in the subrack slots. Slots 1 and 2 are reserved, all remaining slots can be freely occupied:
The wide slot 1 is always occupied with the power supply module (PS 01).
Slot 2 is always occupied with the CPU module (CPU 01).
The remaining slots can be freely occupied with all remaining module types.
The System Scope
Scope The safety-related HIMax controllers are certified for use in process controllers, protective systems, burner systems and machine controllers. All HIMax input and output modules (I/O modules) can be operated with an individual processor module or with several redundant processor modules. When implementing safety-related communications between various devices, ensure that the overall response time does not exceed the fault tolerance time. All calculations must be performed in accordance with the rules specified in Safety Manual HI 800 003 E. Only connect devices with safe electrical isolation to the communications interfaces.
HIMA Module
F3237 | F7105A | F6217 |
F3322 | F7126 | F6705 |
F3330 | F7130 | F7105A |
F3331 | F7130A | F7126 |
F3334 | F7131 | F7130 |
F3417A | F7133 | F7130A |
F3423 | F7553 | F7131 |
F4111A | F8621A | K9202 |
F4204 | F8628X | K9202B |
F6214 | F8641 | K9203 |
F3236 | F8650 | F8628X |
We are service
1.What about the warranty?
1 year warranty.
2. What is the delivery time?
Usually 1-3 Working Days
3.How about the shipment?
We can arrange shipments at competitive prices such as DHL, FedEx, UPS, TNT, etc.
4.What are the payment terms?
Generally, T/T
Product Description
The modular HIMatrix F60 system is composed of a subrack and various modules inserted in the subrack slots. Slots 1 and 2 are reserved, all remaining slots can be freely occupied:
The wide slot 1 is always occupied with the power supply module (PS 01).
Slot 2 is always occupied with the CPU module (CPU 01).
The remaining slots can be freely occupied with all remaining module types.
The System Scope
Scope The safety-related HIMax controllers are certified for use in process controllers, protective systems, burner systems and machine controllers. All HIMax input and output modules (I/O modules) can be operated with an individual processor module or with several redundant processor modules. When implementing safety-related communications between various devices, ensure that the overall response time does not exceed the fault tolerance time. All calculations must be performed in accordance with the rules specified in Safety Manual HI 800 003 E. Only connect devices with safe electrical isolation to the communications interfaces.
HIMA Module
F3237 | F7105A | F6217 |
F3322 | F7126 | F6705 |
F3330 | F7130 | F7105A |
F3331 | F7130A | F7126 |
F3334 | F7131 | F7130 |
F3417A | F7133 | F7130A |
F3423 | F7553 | F7131 |
F4111A | F8621A | K9202 |
F4204 | F8628X | K9202B |
F6214 | F8641 | K9203 |
F3236 | F8650 | F8628X |