The key features of the FBM230:
Four ports, each individually configurable in software for RS-232, RS-422, or RS-485.
Supports RS-232, RS-422, or RS-485 communication interface standards.
I/O software drivers downloadable from a library of available protocols.
Supports up to 2000 DCI block connections.
Communicates with up to 64 RS-485 devices or up to 4 direct connect RS-232 or RS-422 devices.
Integrates field device data into a Foxboro control database.
Field-mounted, suitable for Class G3 (harsh) environments.
Here are the functional specifications for the FBM230:
Module Fieldbus Communication:
Communicates with its associated FCM100ET, FCM100E, FCP270, or FCP280 via the redundant 2 Mbps module Fieldbus.
FBM230 Power Requirements:
7 W (maximum)
7 W (maximum)
24 V DC +5%, -10%
Input Voltage Range (Redundant):
Consumption:
Heat Dissipation:
Operating Conditions:
5 to 95% (non-condensing)
-20 to +70°C (-4 to +158°F)
Temperature:
Relative Humidity:
Storage Conditions:
5 to 95% (non-condensing)
-40 to +70°C (-40 to +158°F)
Temperature:
Relative Humidity:
Dimensions - Module:
284 g (10 oz) approximate
104 mm (4.11 in)
45 mm (1.75 in)
102 mm (4 in), 114 mm (4.5 in) including mounting lugs
Height:
Width:
Depth:
Mass:
Termination Assembly:
272 g (0.6 lb) approximate
363 g (0.8 lb) approximate
Ring Lug (P0926PA):
Compression Screw (RH926GH):
Cables:
Up to 1200 m (3937 ft)
Up to 15 m (50 ft) for custom cables per EIA Standard RS-232.
Type 5 - Refer to Table 1 on page 9
1 m (3.2 ft) to 5 m (16.4 ft)
FBM230 to TA Lengths:
Termination Cable Type:
TA RS-232 Connection (DB-25 Cable) to Modem/Converter/Device:
RS-422 and RS-485:
FUNCTIONAL SPECIFICATIONS
FBM Type | Input Signal | TA Part No |
FBM207 | 16 channel, voltage monitor (external source) 15 to 60 V dc FBM207 channel isolation | P0916AL P0916AN |
FBM207 | 16 channel, voltage monitor 120 V ac or 125 V dc Logic Zero 0 to 20 V ac; 0 to 20 V dc Logic One 80 to 132 V ac; 75 to 150 V dc Input Current for Logic One; 2 mA typical FBM207 channel isolation | P0916AM P0916AP |
FBM207 | 16 channel, voltage monitor 240 V ac Logic Zero 0 to 40 V ac Logic One 160 to 280 V ac Input Current for Logic One; 1.6 mA maximum FBM207 channel isolation | P0916PH P0916PJ |
FBM207 | 16 channel, voltage monitor 120 V ac or 125 V dc with external excitation Logic Zero 0 to 20 V ac; 0 to 20 V dc Logic One 80 to 132 V ac; 75 to 150 V dc Input Current for Logic One; 2 mA typical Group isolation provided by termination assembly | P0916PK P0916PL |
Foxboro Products
FBM205 | FBM230 | P0914QP-OC |
FBM211 | FBM228 | P0914SG-OB |
FBM202 | FBM217 P0914TR | P0914QMJ |
FBM217 | FBM242 P0916TA | P0914RU-OA |
FCM10E | FBM201 P0914SQ | P0914SA-OC |
FBMSVH | FCM2F10 P0916TQ | P0914RD-OE |
FBI10E P0972AJ | IPM2-P0904HA | O0914SK-OA |
FBM42 P0902XB | P0913UU-OA P0913UTR | P0914QX-OC |
FBM04 P0400YE | P0914M8B P0913CX-OD | P0914SG-OA |
FBMSLT | P0913UG-OA P0913UFA | P0914QU-OB |
P0400DA FBM01 | P0913UTC P0913UU-OA | P0914RR-OA |
P0400YC FBM02 | P0914KJE P0914KP-OA | P0923NAB |
P0400YD FBM03 | P0913UU-OB P0913UTD | P0923NAC |
The key features of the FBM230:
Four ports, each individually configurable in software for RS-232, RS-422, or RS-485.
Supports RS-232, RS-422, or RS-485 communication interface standards.
I/O software drivers downloadable from a library of available protocols.
Supports up to 2000 DCI block connections.
Communicates with up to 64 RS-485 devices or up to 4 direct connect RS-232 or RS-422 devices.
Integrates field device data into a Foxboro control database.
Field-mounted, suitable for Class G3 (harsh) environments.
Here are the functional specifications for the FBM230:
Module Fieldbus Communication:
Communicates with its associated FCM100ET, FCM100E, FCP270, or FCP280 via the redundant 2 Mbps module Fieldbus.
FBM230 Power Requirements:
7 W (maximum)
7 W (maximum)
24 V DC +5%, -10%
Input Voltage Range (Redundant):
Consumption:
Heat Dissipation:
Operating Conditions:
5 to 95% (non-condensing)
-20 to +70°C (-4 to +158°F)
Temperature:
Relative Humidity:
Storage Conditions:
5 to 95% (non-condensing)
-40 to +70°C (-40 to +158°F)
Temperature:
Relative Humidity:
Dimensions - Module:
284 g (10 oz) approximate
104 mm (4.11 in)
45 mm (1.75 in)
102 mm (4 in), 114 mm (4.5 in) including mounting lugs
Height:
Width:
Depth:
Mass:
Termination Assembly:
272 g (0.6 lb) approximate
363 g (0.8 lb) approximate
Ring Lug (P0926PA):
Compression Screw (RH926GH):
Cables:
Up to 1200 m (3937 ft)
Up to 15 m (50 ft) for custom cables per EIA Standard RS-232.
Type 5 - Refer to Table 1 on page 9
1 m (3.2 ft) to 5 m (16.4 ft)
FBM230 to TA Lengths:
Termination Cable Type:
TA RS-232 Connection (DB-25 Cable) to Modem/Converter/Device:
RS-422 and RS-485:
FUNCTIONAL SPECIFICATIONS
FBM Type | Input Signal | TA Part No |
FBM207 | 16 channel, voltage monitor (external source) 15 to 60 V dc FBM207 channel isolation | P0916AL P0916AN |
FBM207 | 16 channel, voltage monitor 120 V ac or 125 V dc Logic Zero 0 to 20 V ac; 0 to 20 V dc Logic One 80 to 132 V ac; 75 to 150 V dc Input Current for Logic One; 2 mA typical FBM207 channel isolation | P0916AM P0916AP |
FBM207 | 16 channel, voltage monitor 240 V ac Logic Zero 0 to 40 V ac Logic One 160 to 280 V ac Input Current for Logic One; 1.6 mA maximum FBM207 channel isolation | P0916PH P0916PJ |
FBM207 | 16 channel, voltage monitor 120 V ac or 125 V dc with external excitation Logic Zero 0 to 20 V ac; 0 to 20 V dc Logic One 80 to 132 V ac; 75 to 150 V dc Input Current for Logic One; 2 mA typical Group isolation provided by termination assembly | P0916PK P0916PL |
Foxboro Products
FBM205 | FBM230 | P0914QP-OC |
FBM211 | FBM228 | P0914SG-OB |
FBM202 | FBM217 P0914TR | P0914QMJ |
FBM217 | FBM242 P0916TA | P0914RU-OA |
FCM10E | FBM201 P0914SQ | P0914SA-OC |
FBMSVH | FCM2F10 P0916TQ | P0914RD-OE |
FBI10E P0972AJ | IPM2-P0904HA | O0914SK-OA |
FBM42 P0902XB | P0913UU-OA P0913UTR | P0914QX-OC |
FBM04 P0400YE | P0914M8B P0913CX-OD | P0914SG-OA |
FBMSLT | P0913UG-OA P0913UFA | P0914QU-OB |
P0400DA FBM01 | P0913UTC P0913UU-OA | P0914RR-OA |
P0400YC FBM02 | P0914KJE P0914KP-OA | P0923NAB |
P0400YD FBM03 | P0913UU-OB P0913UTD | P0923NAC |