General Electric Multilin F650BFEF2G0HIC Versatile Feeder Protection Relay

  • F650BFEF2G0HIC

  • GE

  • T/T

  • 12 Months

Availability:
Quantity:


Technical Specifications

SENSITIVE GROUND INSTANTANEOUS OVERCURRENT (50SG)

  • Current: Fundamental Phasor (without harmonics) or RMS

  • Rated current: For connection to 1 or 5 A CTs

  • Pickup level: 0.005 to 16.0 A in steps of 0.001 A

  • Reset dropout level: 97% to 98% of the pickup level

  • Accuracy: ±1.5% of the reading ±1 mA from 0.005 to 16 A

  • Overreach: < 2%

  • Trip Delay: 0.00 to 900.00 s. in steps of 0.01 s.

  • Operate Time: < 30 ms at 3 x Pickup at 50 Hz

  • Reset time: 0.00 to 900.00 s. in steps of 0.01 s.

  • Timing accuracy: at 0ms time delay (no intentional delay): 50 ms; at non-zero time delay: ±3% of operate time or 50 ms (whichever is greater)

ISOLATED GROUND INSTANTANEOUS OVERCURRENT (50IG)

  • Current Input: Fundamental Phasor (without harmonics)

  • Voltage Input: Fundamental Phasor (without harmonics)

  • Current Pickup level: 0.005 to 0.400 A in steps of 0.001 A

  • Voltage Pickup level: 2 to 70 V in steps of 1 V

  • Dropout level: 97 to 98% of the pickup level

  • Level Accuracy: ±1.5% of the reading ±1 mA from 0.005 to 16 A

  • Trip delay: 0.00 to 900.00 s. in steps of 0.01 s.

  • Operate time: <50 ms at 3 x Pickup at 50 Hz, typically

  • Timing accuracy: at 0ms time delay (no intentional delay): 50 ms; at non-zero time delay: ±3% of operate time or 50 ms (whichever is greater)

  • Snapshot Events: Selectable by setting

PHASE DIRECTIONAL UNITS (67P)

  • Directionality: Forward and reverse selectable by setting

  • Polarizing: Quadrature Voltage

    • ABC seq: Phase A (VBC), Phase B (VCA), Phase C (VAB)

    • ACB seq: Phase A (VCB), Phase B (VAC), Phase C (VBA)

  • Polarizing voltage threshold: 0 to 300 Vac in steps of 1 V

  • Current Sensitivity Threshold: 50 mA

  • Characteristic angle: -90º to +90º in steps of 1º

  • Block Logic: Permission or Block selectable by setting

  • Angle accuracy: ±2º for I>0.1 A and V>5 Vac

  • Operate time: <30ms, typically

NEUTRAL AND GROUND DIRECTIONAL UNIT (67N/67G)

  • Directionality: Forward and reverse selectable by setting

  • Polarizing: Voltage, current, dual

  • Polarizing Voltage: VN (measured or calculated, selected by setting)

  • Polarizing Current: Isg (measured from 5th current transformer)

  • Operating Current: Ig (measured from 4th current transformer)

  • Polarizing Voltage threshold: 0 to 300 Vac in steps of 1 V

  • Polarizing Current threshold: 0.005 A

  • Characteristic angle: -90º to +90º in steps of 1º

  • Block Logic: Permission or Block selectable by setting

  • Angle accuracy: ±2º for I>0.1 A and V>5 Vac

  • Operate time: <30ms, typically

SENSITIVE GROUND DIRECTIONAL UNIT (67SG)

  • Polarization By: Voltage

  • Polarization Voltage: 0 to 300 Vac in steps of 1V

  • Directionality: Forward and reverse selectable by setting

  • Characteristic angle: -90º to +90º in steps of 1º

  • Angle accuracy: ±3º from 0.1 A and 5 Vac

  • Response time: <30ms typically

THERMAL MODEL (49)

  • Current: Fundamental phasor (without harmonics)

  • Rated current: Valid for connection to 1 or 5 A CTs

  • Pickup level: 0.05 to 160.00 A in steps of 0.01 A

  • Dropout level: 97% to 98% of the pickup

  • Accuracy: ±0.5% of the reading ±10 mA from 0.05 to 10 A; ±1.5% of the reading for higher values



INST Automation PLC Limited

Vicky Chi

sales3@5gplc.com

+86 18144155716  (Whats-app, Skype, Wechat)



Recommend modules:


Bently Nevada: 3500/22 138607-01, 3500/42M 176449-02, 3500/15 106M1079-01, TK-3E, 3500/05, 3300...
ABB: CI801, IMASO11, PM851K01, 3BHB012961R0001 5SHX2645L0002, HIEE401807R0001, 07AC91...
Allen Bradley: 1756-OF8, 1769-L71, 1756-OX8I, 1756-CNBR, 1756-IF16, 1756-OB16E, 1747-L531...
Honeywell: CC-PDOB01, FC-TSAI-1620M, 900H02-0102, 10201/2/1, 8C-TAIXA1, 51401286-100...
HIMA: F7553, F7126, F8621A, F8650E, F8627X, F8650X, F7133, K9203A, Z7116...
GE: DS200DTBBG1ABB, IC697PWR711, IS220PDIAH1B, 469-P5-HI-A20-E, F35E00VFHF8FH6TM6TPXX, UR1HH, UR8LH...
YOKOGAWA: AAI143-S00, AMM22 S3, CP451-10 S2, AAI543-H03, PW702 S1, AIP502 S1, AAI543-H00...
TRICONEX: 4329, 3008, 3605E, 8111, 3805E, 3625, 4351A, AI3351, DI3301, 4000103-510...
EPRO: MMS6210, A6210, PR9350/02, CON021+PR6423/00R-030, A6220, CON011...
Ovation: 5X00226G02, 1C31222G01, 1P00028G01, 5X00119G01, 1X00781H01L, 5X00241G01...
Delta V: KJ3202X1-BA1, KJ4001X1-CA1, KJ4001X1-BE1 12P0818X072, KJ2005X1-MQ1...
Schneider: 140DAI74000, 140CPU65150, TSXSUP702, 140CPS11420, BMXFTB2010, 170ADI34000...
ICS Triplex: T8100, T9432, T8461C, T3401, T9100, T8151B, 9802, T9310-02...
Foxboro: FBM202, FBM242 P0916TA, P0400DA FBM01, FCM2F10 P0916TQ, FBM204...
Siemens: 6DD1600-0AJ0, 6ES5948-3UR23, 6ES7193-4CD20-0AA0, 6GK1100-0AG01, A5E00103265...
WOODWARD: 8200-226, 9907-164, 5466-1000, 9907-167, 5466-411, 9907-014, 8400-016...


Brands 拷贝 2

Previous: 
Next: