Honeywell 51309276-150 Process Manager (HPM) I/O Link Module
Home » Products » Honeywell » Honeywell 51309276-150 Process Manager (HPM) I/O Link Module

Product Category

Contact Us

Email:sales3@5gplc.com

Address:No.601, Hongwen Liuli, Siming District, Xiamen, China

Honeywell 51309276-150 Process Manager (HPM) I/O Link Module Honeywell 51309276-150 Process Manager (HPM) I/O Link Module
Honeywell 51309276-150 Process Manager (HPM) I/O Link Module Honeywell 51309276-150 Process Manager (HPM) I/O Link Module
Honeywell 51309276-150 Process Manager (HPM) I/O Link Module Honeywell 51309276-150 Process Manager (HPM) I/O Link Module
Honeywell 51309276-150 Process Manager (HPM) I/O Link Module Honeywell 51309276-150 Process Manager (HPM) I/O Link Module
Honeywell 51309276-150 Process Manager (HPM) I/O Link Module Honeywell 51309276-150 Process Manager (HPM) I/O Link Module

loading

Honeywell 51309276-150 Process Manager (HPM) I/O Link Module

  • 51309276-150

  • Honeywell

  • T/T

  • 1 year

Availability:
Quantity:

The Honeywell 51309276-150 is a High Performance Process Manager (HPM) I/O Link Module. It is used to interface high-performance I/O devices to the HPM subsystem. The module has eight channels of analog input, eight channels of analog output, and 16 channels of digital I/O.



Features:

  • Eight channels of analog input

  • Eight channels of analog output

  • 16 channels of digital I/O

  • Compatible with a wide range of HPM systems

  • Rugged and reliable

  • Easy to install and maintain



Applications:

  • Industrial process control

  • Manufacturing automation

  • Building automation

  • Power generation

  • Oil and gas



8C-PAOH51 - 副本


Description

This command triggers a redundant controller pair in the Synchronization Maintenance State to enter the Standby State. While in the Standby State, the secondary controller contains a database that was previously synchronized with the primary controller but the secondary is no longer receiving synchronization-data updates from the primary controller. Specifically, after entering the Standby State, issue the switchover command, and the controller with the stale database switches into the primary role with the CEE execution state set to Idle. In the case where the Standby State was achieved through the Enable Standby command, the Disable Synchronization command exits the Standby State.


Products Of Other Brands

3BSE030220R1 CI854AK01 EX06100 F3421 SY-61025004R-AS
3BSE018100R1 PM860K01 EX06101 Z1001 BS811TQB
3BSE022360R1 DI802 EX06102 Z6018 B1279EN
3BSE013230R1 TU810V1 EX06104 B5322 1040052B
3BSE018168R1 PM851K01 EX06105 F7546 SY-60301003RB
3BSE018157R1 PM861AK01 EX06106 F7126 SY-61025003R-AS
3BSE040364R1 TU834 EX06071 F7131 0301066 025125-AS
3BSE020850R1 TU842 EX06098 F8650X 0303474A
3BSE02445R1 TU844 1C31122G01 F8621A SY-0399194C

                                                                                                                                        

Brands=

Previous: 
Next: