Honeywell CC-TDOR01 Digital Output Relay Module
Home » Products » Honeywell » Honeywell CC-TDOR01 Digital Output Relay Module

Product Category

Contact Us

Email:sales3@5gplc.com

Address:No.601, Hongwen Liuli, Siming District, Xiamen, China

Honeywell CC-TDOR01 Digital Output Relay Module

  • CC-TDOR01

  • Honeywell

  • T/T

  • 1 year

Availability:
Quantity:

Honeywell CC-TDOR01 is a digital output relay module which has 32 IOTA channels. There are many functions to be done via IOTA (Input/Output Terminal Adapter). Those functions include reading of I/O, programming of I/O and configuration of I/O communication channels. I/O module has 3 pin terminals per each IOTA channel, which are signal, common and 24DCV.


Specifications

  • Type of the I/O module: Digital output relay module

  • IOTA channels: 32

  • Max DC current per channel: 3A

  • Communication protocol: MODBUS RTU


Technical Specifications:

  • Part Number: CC-TDOR01

  • Manufacturer: Honeywell

  • Product Type: Digital Output Relay Module

  • Number of Channels: 32

  • Contact Type: Dry Contact

  • Contact Rating: 3A per contact

  • Operating Mode: Sinking or Sourcing

  • Maximum Load: 3A per contact

  • Dimensions: 30 x 20 x 20 cm

  • Weight: 2 kg


Features:

  • 32 3A dry contacts

  • Sinking or sourcing operation

  • Maximum load of 3A per contact

  • Compact design




8C-PAOH51 - 副本


Description

This command triggers a redundant controller pair in the Synchronization Maintenance State to enter the Standby State. While in the Standby State, the secondary controller contains a database that was previously synchronized with the primary controller but the secondary is no longer receiving synchronization-data updates from the primary controller. Specifically, after entering the Standby State, issue the switchover command, and the controller with the stale database switches into the primary role with the CEE execution state set to Idle. In the case where the Standby State was achieved through the Enable Standby command, the Disable Synchronization command exits the Standby State.


Products Of Other Brands

3BSE030220R1 CI854AK01 EX06100 F3421 SY-61025004R-AS
3BSE018100R1 PM860K01 EX06101 Z1001 BS811TQB
3BSE022360R1 DI802 EX06102 Z6018 B1279EN
3BSE013230R1 TU810V1 EX06104 B5322 1040052B
3BSE018168R1 PM851K01 EX06105 F7546 SY-60301003RB
3BSE018157R1 PM861AK01 EX06106 F7126 SY-61025003R-AS
3BSE040364R1 TU834 EX06071 F7131 0301066 025125-AS
3BSE020850R1 TU842 EX06098 F8650X 0303474A
3BSE02445R1 TU844 1C31122G01 F8621A SY-0399194C

                                                                                                                                        