TC-FPCXX2
Honeywell
T/T, Western
12 Months
Availability: | |
---|---|
Quantity: | |
Uncoated Models:
TC-FPCXX2
TC-FPDXX2
Coated Models:
TK-FPCXX2
TK-FPDXX2
Input Voltage Range:
85-132 VAC or 170-265 VAC (selectable)
19.2-32 VDC
Note: Input may drop to 16 V for a maximum of 2 minutes each hour for motor starting.
Input Power:
150 VA, 92 W for TC-FPCXX2
100 W for TC-FPDXX2
Maximum Inrush Current:
15 A for TC-FPCXX2
30 A for TC-FPDXX2
Frequency Range:
47-63 Hz for AC
DC for DC input
Total Power Output (maximum):
70 W @ 60°C
Backplane Output Current (maximum):
1.5 A @ 1.2 V
4 A @ 3.3 V
10 A @ 5.1 V
2.8 A @ 24.0 V
Note: The combination of all output power cannot exceed 70 W.
Fuse Protection:
Non-replaceable fuse soldered in place, intended to guard against fire hazards due to short circuit conditions.
Wiring:
#14 AWG (1.4 mm)
Dimensions (L x D x H):
11.2 x 14.5 x 14.0 cm (4.41 x 5.71 x 5.51 in)
Weight:
Approx. 1.1 kg (2.5 lb.)
Location:
Left side of chassis (does not consume a slot)
Earlier models were rated as follows:
TC-FPCXX1: 55 W @ 60°C; 70 W @ 45°C
TC-FPDXX1: 50 W @ 60°C; 70 W @ 40°C
Why do they ?
Prerequisites • These procedures can only be performed while off process. • We recommend that you proceed with extreme caution whenever replacing any component in a control system. • Be sure the system is offline or in a safe operating mode. • Component replacements may also require corresponding changes in the control strategy configuration through Control Builder, as well as downloading appropriate data to the replaced component. • Note that all modules are keyed. 1 Loosen screws at each side of the module cover that secures the controller module to the IOTA board. 2 Carefully remove the Controller module from the IOTA board and connector.
What we serve?
What is the MOQ: 1 piece
Warranty time: 1 year
Payment Term: 100% Payment in Advance
Courier partners: DHL, UPS, TNT, FedEx...
Lead time: 1-3 working day
More products
3500/32 | 125712-01 | SPDSI13 | BRC300 |
3500/42M | 140734-02 | SPNIS21 | SPNPM22 |
3500/20 | 125744-02 | SPNPM22 | IMMFP12 |
3500/50 | 133388-02 | SPASI23 | SPHSS03 |
3500/15 | 127610-01 | SPDSO14 | SPIET800 |
3500/25 | 149369-01 | SPFEC12 | SPBRC410 |
1.Allen Bradley 1756/1746/1747/1785 Series
2.ABB 800xA/Bailey INFI90/DSQC/ Series
3.Bently Nevada 3500/3300 Monitoring System
4.General electric IC693/IC697/IC698/IS200/DS200 Series
5.Honeywell TDC2000/TDC3000/Experion HS Series
6.Invensys Triconex Redundant fault-tolerant control system
Most modern fault-tolerant controller based on Triple Modular Redundancy (TMR) architecture
7. OVATION system spare parts
8.Schneider Series Quantum 140 series
Uncoated Models:
TC-FPCXX2
TC-FPDXX2
Coated Models:
TK-FPCXX2
TK-FPDXX2
Input Voltage Range:
85-132 VAC or 170-265 VAC (selectable)
19.2-32 VDC
Note: Input may drop to 16 V for a maximum of 2 minutes each hour for motor starting.
Input Power:
150 VA, 92 W for TC-FPCXX2
100 W for TC-FPDXX2
Maximum Inrush Current:
15 A for TC-FPCXX2
30 A for TC-FPDXX2
Frequency Range:
47-63 Hz for AC
DC for DC input
Total Power Output (maximum):
70 W @ 60°C
Backplane Output Current (maximum):
1.5 A @ 1.2 V
4 A @ 3.3 V
10 A @ 5.1 V
2.8 A @ 24.0 V
Note: The combination of all output power cannot exceed 70 W.
Fuse Protection:
Non-replaceable fuse soldered in place, intended to guard against fire hazards due to short circuit conditions.
Wiring:
#14 AWG (1.4 mm)
Dimensions (L x D x H):
11.2 x 14.5 x 14.0 cm (4.41 x 5.71 x 5.51 in)
Weight:
Approx. 1.1 kg (2.5 lb.)
Location:
Left side of chassis (does not consume a slot)
Earlier models were rated as follows:
TC-FPCXX1: 55 W @ 60°C; 70 W @ 45°C
TC-FPDXX1: 50 W @ 60°C; 70 W @ 40°C
Why do they ?
Prerequisites • These procedures can only be performed while off process. • We recommend that you proceed with extreme caution whenever replacing any component in a control system. • Be sure the system is offline or in a safe operating mode. • Component replacements may also require corresponding changes in the control strategy configuration through Control Builder, as well as downloading appropriate data to the replaced component. • Note that all modules are keyed. 1 Loosen screws at each side of the module cover that secures the controller module to the IOTA board. 2 Carefully remove the Controller module from the IOTA board and connector.
What we serve?
What is the MOQ: 1 piece
Warranty time: 1 year
Payment Term: 100% Payment in Advance
Courier partners: DHL, UPS, TNT, FedEx...
Lead time: 1-3 working day
More products
3500/32 | 125712-01 | SPDSI13 | BRC300 |
3500/42M | 140734-02 | SPNIS21 | SPNPM22 |
3500/20 | 125744-02 | SPNPM22 | IMMFP12 |
3500/50 | 133388-02 | SPASI23 | SPHSS03 |
3500/15 | 127610-01 | SPDSO14 | SPIET800 |
3500/25 | 149369-01 | SPFEC12 | SPBRC410 |
1.Allen Bradley 1756/1746/1747/1785 Series
2.ABB 800xA/Bailey INFI90/DSQC/ Series
3.Bently Nevada 3500/3300 Monitoring System
4.General electric IC693/IC697/IC698/IS200/DS200 Series
5.Honeywell TDC2000/TDC3000/Experion HS Series
6.Invensys Triconex Redundant fault-tolerant control system
Most modern fault-tolerant controller based on Triple Modular Redundancy (TMR) architecture
7. OVATION system spare parts
8.Schneider Series Quantum 140 series