Origin New HIMA B9302-0.5 IO Rack 16 Slot
Home » Products » HIMA » Origin New HIMA B9302-0.5 IO Rack 16 Slot

Product Category

Contact Us

Email:sales3@5gplc.com

Address:No.601, Hongwen Liuli, Siming District, Xiamen, China

Origin New HIMA B9302-0.5 IO Rack 16 Slot

  • B9302-0.5

  • HIMA

  • T/T

  • 12 Months

Availability:
Quantity:

The HIMA B9302-0.5 is a 19-inch, 4U high rack-mounted safety controller with 16 I/O slots and a 0.5m I/O bus cable. It is a member of the HIMA B9302 family of safety controllers, which are designed for use in applications where the highest level of safety and reliability are required.



The B9302-0.5 has a number of features that make it well-suited for use in safety-critical applications, including:

  • IEC 61508 SIL 3 and EN 62061 SIL 3 certified: This means that the B9302-0.5 has been independently tested and certified to meet the highest standards for safety and reliability.

  • Redundant hardware design: The B9302-0.5 has a redundant hardware design that helps to ensure that the system will continue to operate even if one component fails.

  • Hot-swappable modules: The B9302-0.5's modules are hot-swappable, which means that they can be replaced without having to shut down the system. This helps to minimize downtime and ensure the continued operation of the safety system.

  • Wide range of I/O modules: The B9302-0.5 supports a wide range of I/O modules, which gives users the flexibility to configure the system to meet their specific needs.

  • Easy-to-use programming software: The B9302-0.5 is programmed using the HIMA ProSIL software, which is a user-friendly and powerful programming tool.



The B9302-0.5 is typically used in safety-critical applications such as:

  • Process control systems: The B9302-0.5 can be used to implement safety functions in process control systems, such as overspeed protection, emergency shutdown, and fire protection.

  • Machine control systems: The B9302-0.5 can be used to implement safety functions in machine control systems, such as two-hand control, safety interlocks, and emergency stop.

  • Power generation and distribution systems: The B9302-0.5 can be used to implement safety functions in power generation and distribution systems, such as generator protection, grid protection, and transformer protection.



HIMA Automation Modules

HIMA
F3421 BV7032-0 F3322
Z1001 BV7046-4 F6251
Z6018 BV7040-4 F3330
B5322 HIMA F3330 F8627
F7546 F8203 F3236
F7126 F2 DO 8 01(F2DO8 01) F3330
F7131 F7133 F6217
F8650X F3300 F8650X
F8621A B5322 F7131
Z6011 F3236 F2DO1601
Z6013 F8627X F8640



HIMA



If you have any inquiry, pls contact me any time !

Allen-Bradley ( 1747-L533, 1756-EN2T, 1756-L71,1756-L73... )

Bently Nevada ( 3500/25, 3500/22M, 3500/42M, 1900/65A )

Honeywell ( 8C-PDOD51, 8C-TAID51,CC-PAOH01,10100/2/1...)

ABB (07KT98,SPBRC410,SPAS011,PM861AK01...)

GE Fanuc (IS210AEBIH1BAB,IS220PSCAH1A IS220PAICH2A,DS200RTBAG3AHC...)

Invensys Triconex (3008,3721, 3503E,3625...)

Hima  ( F8650X, F8627X, F3236,F8621A,F2DO1601...)

Yokogawa (CP451-10,CP451-50,CP451-11,CP461,VI701...)


Previous: 
Next: