AAP135-S00
Yokogawa
T/T
12 Months
Availability: | |
---|---|
Quantity: | |
Pulse Input Module (Isolated Channels)
Model: AAP135
Number of Input Channels: 8, isolated channels
Input Signal:
2-wire type: Contact ON/OFF, voltage pulse, current pulse (possible to supply transmitter power supply)
3-wire type: Power-supply-type voltage pulse
Input Frequency: 0 to 10 kHz
Withstanding Voltage:
Between input and system: 500 V AC, for 1 minute
Between channels: 500 V AC, for 1 minute
Minimum Input Pulse Width: 40 µs
Input Signal Level:
VH (high level): 3 to 24 V DC
VL (low level): -1 to 8 V DC
VH-VL (swing value): 3 V or higher
When supplying 12 V DC: 15 V DC 15 mA or higher
When supplying 24 V DC: 30 V DC 30 mA or higher
Open: 100 kΩ or larger, Close: 200 Ω or less
Contact input: Open/close levels of relay contact and transistor contact
Contact capacity:
Voltage/current pulse input (Current input is converted to voltage.):
Signal source resistance: 1 kΩ or less
Shunt Resistance: Can be selected from none/200/500/1000 Ω. (Open when power is OFF and for the standby side in a dual-redundant configuration)
Pull-up Resistance: 68 kΩ (12 V DC or 24 V DC)
Filter: Filter for eliminating chattering can be set.
Data Update Period: 2 ms
Transmitter Power Supply: Can select 24 V DC/12 V DC.
Limiter Value: 12 V DC ±10 %: 40 mA, 24 V DC ±10 %: 30 mA
Maximum Current Consumption: 300 mA (5 V DC), 400 mA (24 V DC)
Weight: 0.3 kg
External Connection: Pressure clamp terminal, KS cable, MIL connector cable
There are 8 types of analog I/O modules (with HART communication function)
Model | Model Name | Function |
AAI141-H | Analog Input Module (Current Input) | 16-channel, 4 to 20 mA, non-isolated |
AAB141-H | Analog Input Module (Voltage/current Input) | 16-channel, 1 to 5 V/4 to 20 mA, non-isolated |
AAI841-H | Analog I/O Module (Current I/O) | 8-channel input/8-channel output, 4 to 20 mA, non-isolated |
AAB842-H | Analog I/O Module (Voltage/current Input, Current Output) | Analog I/O Module (Voltage/current Input, Current Output) |
AAI135-H | Analog Input Module (Current Input) | 8-channel, 4 to 20 mA, isolated channels |
AAI835-H | Analog I/O Module (Current I/O) | 4-channel input/4-channel output, 4 to 20 mA, isolated channels |
AAI143-H | Analog Input Module (Current Input) | 16-channel, 4 to 20 mA, isolated |
AAI543-H | Analog Output Module (Current Output) | 16-channel, 4 to 20 mA, isolated |
Other Yokogawa Products
MAC2*A | ADV551-P00 | PW302 S4 |
MX6*A | AAR145-S00 | CP461-50 |
PAC*A | CP451-10 | AIP502 S1 |
LCA*C | VI701 | SB302 S1 |
PS11*C | VI702 | CP345 S1 |
VM1*D | PW302 | AIP532 S1 |
VM2*D | CP345 | PW302 S4 |
ST3*D | AIP532 | AFG84D-H4123 |
AD5*D | AIP502 | ATK4A-00 |
NM6*D | AIP601 | CP451-11 |
ST4*D | CP461 | CP701/S1 |
NC2*C | AAM11 | AAR181-S00 S2 |
Pulse Input Module (Isolated Channels)
Model: AAP135
Number of Input Channels: 8, isolated channels
Input Signal:
2-wire type: Contact ON/OFF, voltage pulse, current pulse (possible to supply transmitter power supply)
3-wire type: Power-supply-type voltage pulse
Input Frequency: 0 to 10 kHz
Withstanding Voltage:
Between input and system: 500 V AC, for 1 minute
Between channels: 500 V AC, for 1 minute
Minimum Input Pulse Width: 40 µs
Input Signal Level:
VH (high level): 3 to 24 V DC
VL (low level): -1 to 8 V DC
VH-VL (swing value): 3 V or higher
When supplying 12 V DC: 15 V DC 15 mA or higher
When supplying 24 V DC: 30 V DC 30 mA or higher
Open: 100 kΩ or larger, Close: 200 Ω or less
Contact input: Open/close levels of relay contact and transistor contact
Contact capacity:
Voltage/current pulse input (Current input is converted to voltage.):
Signal source resistance: 1 kΩ or less
Shunt Resistance: Can be selected from none/200/500/1000 Ω. (Open when power is OFF and for the standby side in a dual-redundant configuration)
Pull-up Resistance: 68 kΩ (12 V DC or 24 V DC)
Filter: Filter for eliminating chattering can be set.
Data Update Period: 2 ms
Transmitter Power Supply: Can select 24 V DC/12 V DC.
Limiter Value: 12 V DC ±10 %: 40 mA, 24 V DC ±10 %: 30 mA
Maximum Current Consumption: 300 mA (5 V DC), 400 mA (24 V DC)
Weight: 0.3 kg
External Connection: Pressure clamp terminal, KS cable, MIL connector cable
There are 8 types of analog I/O modules (with HART communication function)
Model | Model Name | Function |
AAI141-H | Analog Input Module (Current Input) | 16-channel, 4 to 20 mA, non-isolated |
AAB141-H | Analog Input Module (Voltage/current Input) | 16-channel, 1 to 5 V/4 to 20 mA, non-isolated |
AAI841-H | Analog I/O Module (Current I/O) | 8-channel input/8-channel output, 4 to 20 mA, non-isolated |
AAB842-H | Analog I/O Module (Voltage/current Input, Current Output) | Analog I/O Module (Voltage/current Input, Current Output) |
AAI135-H | Analog Input Module (Current Input) | 8-channel, 4 to 20 mA, isolated channels |
AAI835-H | Analog I/O Module (Current I/O) | 4-channel input/4-channel output, 4 to 20 mA, isolated channels |
AAI143-H | Analog Input Module (Current Input) | 16-channel, 4 to 20 mA, isolated |
AAI543-H | Analog Output Module (Current Output) | 16-channel, 4 to 20 mA, isolated |
Other Yokogawa Products
MAC2*A | ADV551-P00 | PW302 S4 |
MX6*A | AAR145-S00 | CP461-50 |
PAC*A | CP451-10 | AIP502 S1 |
LCA*C | VI701 | SB302 S1 |
PS11*C | VI702 | CP345 S1 |
VM1*D | PW302 | AIP532 S1 |
VM2*D | CP345 | PW302 S4 |
ST3*D | AIP532 | AFG84D-H4123 |
AD5*D | AIP502 | ATK4A-00 |
NM6*D | AIP601 | CP451-11 |
ST4*D | CP461 | CP701/S1 |
NC2*C | AAM11 | AAR181-S00 S2 |