T8800
ICS Triplex
T/T
1 year
Availability: | |
---|---|
Quantity: | |
Manufacturer: ICS Triplex
Model: T8800
Input Voltage: 24V DC
Operating Temperature: -20℃ to 60℃
Supported Protocols:
Modbus
TCP/IP
Ethernet/IP
RAM Capacity: 2GB
Flash Memory Capacity: 16GB
Dimensions: 100mm × 50mm × 30mm
Material: Stainless Steel
Protection Level: IP67
Certifications:
CE
RoHS
Input Channels: 40 input channels per FTA (Field Termination Assembly)
Interface: Acts as the main interface between a field device generating a digital signal and the Trusted TMR 24 Vdc Digital Input Module T8403.
Connections: Industry-standard field device connections (2-wire).
Installation Compatibility: Standard DIN rail compatibility.
High Performance: Designed for demanding process control applications with robust memory and communication capabilities.
Environmental Protection: IP67 rating ensures high protection against dust and water, making it suitable for harsh industrial environments.
Modular Design: Facilitates easy expansion and integration into existing systems.
Stainless Steel Construction: Provides durability and resistance to corrosion.
Industry Certifications: Compliance with CE and RoHS standards ensures adherence to safety and environmental regulations.
Standard DIN Rail Compatibility: Simplifies installation and integration with existing systems.
Description
Each I/O module in a 8000 Series System may have a Companion Slot configured via a double-width I/O connector, but not necessarily occupied. This enables a faulty module to be replaced without disrupting the System. Replacement is effected by simply inserting a working module of the same type, with compatible firmware and hardware, in the adjacent slot. The 8000 Series TMR Processor automatically initiates the education of the replacement module with the appropriate data. This is indicated by the Educated LED flashing. When education is complete, the Educated LED becomes steady green, the previously active faulty module indicates ‘standby’ and the replacement module indicates ‘active’. Check that the remaining LEDs on the front panel of the replacement module are healthy (refer to section 4, Module Status Indicators). The faulty module should be removed from the System and repaired. The 8000 Series System should have a module back in the left hand (primary) slot as soon as a working module is available. Insert the new module in the left hand (primary) slot and initiate a changeover by opening the ejector levers on the right hand (companion slot) module. DO NOT REMOVE THE RIGHT HAND MODULE until the changeover has completed, the left hand module indicates ‘active’ and the right hand module indicates ‘standby’. The right hand module can now be removed.
ICS Triplex Main Products
T8311 | T8232 | T8902 | T8846 | T8840 |
T8472 | T8830 | T8871 | T8160 | T8403 |
T8461 | T8423 | T8402 | T8312-4 | T8800 |
T8202 | T8821 | T8480 | T8234 | T8424 |
T8870 | T9852 | T8380 | T8120 | T8293 |
T8903 | T8273 | T8270 | T8294 | T8194 |
Strong PLC Parts Series:
ABB PLC
DCS 800xA System/S800 I/O System, ADCS 800xA System/S900 I/O Series, Advant OCS/800XA , H&B Freelance 2000 , BAILEY-INFI90/Bailey Net 90, DSQC Robot Parts, PLC cards and boards
Honeywell DCS
Experion PKS ( C200 , C300 ), FSC
Bently Nevada TSI
Bently Nevada 3500 Series Monitor system, Bently Nevada 3300 Series Monitor system
Modules/Chassis/I/O Module, Power Supply Module/Proximitor Sensor/ Programming Cable
Fanuc PLC
IC695, IC698, IC694, IC697, IC754, IC752 QuickPanel, IC660, IC600 Seriex Six, IC610, IC620 Series One, IC692 Series 90-20, IS200, IS215, DS200, DS3000/3800
Invensys Foxboro DCS
Foxboro I/A Series System Module.Foxboro CP /Foxboro FBM , Foxboro Termination Assembly Module, Foxboro Baseplate
InvensysTriconex DCS
Triconex Rack, Triconex Power Module, Processor Module, Input Module, Output Module, Tricon Communication Module TCM, Triconex Terminal Block, Triconex Cable
Yokogawa PLC
Yokogawa CENTUM CS 3000 R3/Yokogawa CPU Module/Power Supply Module/ I/O Module/Cards
More Products
F31X139APMALG2FR01 | NCNI P0972PP | 4500 | 07KT97 GJR5253000R0270 |
HE693THM884 | P0926HM | DI3301 | 07KT98 GJR5253100R0220 |
IC693MDL640 | FBM218 P0922VW | 2752 | 07AI91 WT91 GJR5251600R4202 |
IC697PCM711 | CP40 | 3511 | 07BT62R1 |
VCIB-16A | P0926HT | 4351B | 07CR41-C12 |
IC697MEM715B | FBM204 P0914SY | NCM4320 | 07DC91 |
IC697CPU772 | FCM100ET P0926GS | 3805E | 07DC91 GJR5251400R0202 |
IC3000CS200M | AD916AE | 3401 | 07DC92 |
DS200RTBAG3AEB | P0926JC | 3510 | 07DC92 GJR5251600R0202 |
DS200TBQCG1ABB | ZCP270 P0926CP-0E | 3482 | 07DC92 GJR5252200R0101 |
531X305NTBAPG1 | P0961BS-OC | 3301 | 07DI92 |
FAQ
1.Is the part new?
Yes, 100% Original brand new
2.How is the package?
Original factory seal packed
3.What is the lead time?
In stock: 1-3 working days
4.What is the MOQ:
1pcs
5.What is the payment term:
T/T
6.What is the warranty time?
One year
Manufacturer: ICS Triplex
Model: T8800
Input Voltage: 24V DC
Operating Temperature: -20℃ to 60℃
Supported Protocols:
Modbus
TCP/IP
Ethernet/IP
RAM Capacity: 2GB
Flash Memory Capacity: 16GB
Dimensions: 100mm × 50mm × 30mm
Material: Stainless Steel
Protection Level: IP67
Certifications:
CE
RoHS
Input Channels: 40 input channels per FTA (Field Termination Assembly)
Interface: Acts as the main interface between a field device generating a digital signal and the Trusted TMR 24 Vdc Digital Input Module T8403.
Connections: Industry-standard field device connections (2-wire).
Installation Compatibility: Standard DIN rail compatibility.
High Performance: Designed for demanding process control applications with robust memory and communication capabilities.
Environmental Protection: IP67 rating ensures high protection against dust and water, making it suitable for harsh industrial environments.
Modular Design: Facilitates easy expansion and integration into existing systems.
Stainless Steel Construction: Provides durability and resistance to corrosion.
Industry Certifications: Compliance with CE and RoHS standards ensures adherence to safety and environmental regulations.
Standard DIN Rail Compatibility: Simplifies installation and integration with existing systems.
Description
Each I/O module in a 8000 Series System may have a Companion Slot configured via a double-width I/O connector, but not necessarily occupied. This enables a faulty module to be replaced without disrupting the System. Replacement is effected by simply inserting a working module of the same type, with compatible firmware and hardware, in the adjacent slot. The 8000 Series TMR Processor automatically initiates the education of the replacement module with the appropriate data. This is indicated by the Educated LED flashing. When education is complete, the Educated LED becomes steady green, the previously active faulty module indicates ‘standby’ and the replacement module indicates ‘active’. Check that the remaining LEDs on the front panel of the replacement module are healthy (refer to section 4, Module Status Indicators). The faulty module should be removed from the System and repaired. The 8000 Series System should have a module back in the left hand (primary) slot as soon as a working module is available. Insert the new module in the left hand (primary) slot and initiate a changeover by opening the ejector levers on the right hand (companion slot) module. DO NOT REMOVE THE RIGHT HAND MODULE until the changeover has completed, the left hand module indicates ‘active’ and the right hand module indicates ‘standby’. The right hand module can now be removed.
ICS Triplex Main Products
T8311 | T8232 | T8902 | T8846 | T8840 |
T8472 | T8830 | T8871 | T8160 | T8403 |
T8461 | T8423 | T8402 | T8312-4 | T8800 |
T8202 | T8821 | T8480 | T8234 | T8424 |
T8870 | T9852 | T8380 | T8120 | T8293 |
T8903 | T8273 | T8270 | T8294 | T8194 |
Strong PLC Parts Series:
ABB PLC
DCS 800xA System/S800 I/O System, ADCS 800xA System/S900 I/O Series, Advant OCS/800XA , H&B Freelance 2000 , BAILEY-INFI90/Bailey Net 90, DSQC Robot Parts, PLC cards and boards
Honeywell DCS
Experion PKS ( C200 , C300 ), FSC
Bently Nevada TSI
Bently Nevada 3500 Series Monitor system, Bently Nevada 3300 Series Monitor system
Modules/Chassis/I/O Module, Power Supply Module/Proximitor Sensor/ Programming Cable
Fanuc PLC
IC695, IC698, IC694, IC697, IC754, IC752 QuickPanel, IC660, IC600 Seriex Six, IC610, IC620 Series One, IC692 Series 90-20, IS200, IS215, DS200, DS3000/3800
Invensys Foxboro DCS
Foxboro I/A Series System Module.Foxboro CP /Foxboro FBM , Foxboro Termination Assembly Module, Foxboro Baseplate
InvensysTriconex DCS
Triconex Rack, Triconex Power Module, Processor Module, Input Module, Output Module, Tricon Communication Module TCM, Triconex Terminal Block, Triconex Cable
Yokogawa PLC
Yokogawa CENTUM CS 3000 R3/Yokogawa CPU Module/Power Supply Module/ I/O Module/Cards
More Products
F31X139APMALG2FR01 | NCNI P0972PP | 4500 | 07KT97 GJR5253000R0270 |
HE693THM884 | P0926HM | DI3301 | 07KT98 GJR5253100R0220 |
IC693MDL640 | FBM218 P0922VW | 2752 | 07AI91 WT91 GJR5251600R4202 |
IC697PCM711 | CP40 | 3511 | 07BT62R1 |
VCIB-16A | P0926HT | 4351B | 07CR41-C12 |
IC697MEM715B | FBM204 P0914SY | NCM4320 | 07DC91 |
IC697CPU772 | FCM100ET P0926GS | 3805E | 07DC91 GJR5251400R0202 |
IC3000CS200M | AD916AE | 3401 | 07DC92 |
DS200RTBAG3AEB | P0926JC | 3510 | 07DC92 GJR5251600R0202 |
DS200TBQCG1ABB | ZCP270 P0926CP-0E | 3482 | 07DC92 GJR5252200R0101 |
531X305NTBAPG1 | P0961BS-OC | 3301 | 07DI92 |
FAQ
1.Is the part new?
Yes, 100% Original brand new
2.How is the package?
Original factory seal packed
3.What is the lead time?
In stock: 1-3 working days
4.What is the MOQ:
1pcs
5.What is the payment term:
T/T
6.What is the warranty time?
One year