G122-202-A001
MOOG
T/T
1 year
Availability: | |
---|---|
Quantity: | |
The G122-202A1 Servoamplifier Card by Moog is a differential amplifier with a PID control section designed to drive electro-hydraulic servovalves in closed-loop control systems. It can also be used in applications requiring a current or voltage output proportional to a command signal or the difference between command and feedback signals.
Key Specifications:
Power Supply:
±15 VDC stabilized (25 mA each)
±24 VDC (valve + relay current)
Input Voltage Range:
Pins 3, 7: ±10 VDC
Pin 9: 0 to 120 VDC
Output Capability:
Max current: ±100 mA
Max voltage: ±10 V
Output Ranges:
Selectable with R34: 10, 20, 50, and 100 mA
Proportional Gain:
Adjustable from 5 to 200 mA/V
Linearity:
±3% of full scale
Frequency Response:
-3 dB at frequencies > 800 Hz with inductive load (1 Henry)
Dither:
Amplitude: 0 to 40% valve drive
Frequency: 25 to 300 Hz
External Controlled Relay:
Consumption: 8 mA @ 24 VDC
Contact rating: 1 A/125 VDC, 30 W max.
Dimensions:
3U x 7HP, Euro card format (100 x 160 mm)
Ramp Rate:
0.5 V/s to 20 V/s
Inverter Accuracy:
±1% of applied signal
4-20 mA Converter Accuracy:
±1% of full scale
FGU130B | NB2W90R-11 | NP1AY02-MR |
NB2W56R | CTHMIMOD-00 | NP1AXH8VG-MR |
FTU612A | NP1AXH8V-MR | NP1AXH4DG-MR |
NC1X6406 | FNC160A-C20 | NR1TW-16T65DT |
NP1F-MM1 | NP1X1611-RI | NR1DY-16T05DT |
NP1W1606T | NP1Y16T10P2 | NR1SW-16T65DT |
Description
IEC Standards testing procedures require that the mechanical durability test be carried out without current flowing in the main circuit, with the rated voltage applied to the coil and for at least as many on-off operation cycles as specified for the corresponding intermittent duty class as shown in the table on page 5. The mechanical life of the contactor is inversely proportional to the third or fourth power of the operating voltage. Therefore, if the control circuit voltage is 10% higher than the coil’s rated voltage, the mechanical durability will be reduced by half. An increase in control circuit voltage will harm the operating mechanism, core and shading coil. The results of the mechanical durability test for SC series contactors are given in the table below. The electrical durability test must be carried out for the number of operation cycles specified for the corresponding intermittent duty class shown in the table on page 5, and under the circuit conditions of the corresponding utilization category as defined in the table on page 4. Contact wear is caused by arcing that occurs between contacts when the current is interrupted. The amount of contact wear is directly proportional to approximately the second power of the interrupted current value. Therefore, when a contactor is used for inching or plugging operations, the expected service life of the contacts will be much less than if used for normal operations.
More Products
Fuji | Prosoft | Bently Nevada | Schneider |
NP1W1606T | MVI69L-MBS | 1900/65A | 490NRP25300 |
NP1F-MM1 | MVI46-MBP | 3500/65-01-01 | 140AII33010 |
FTU612A | MVI69-MCM | 3500/42 138700-01 | 140XTS00200 |
FGU130B | MVI56E-GSC | 330180-91-05 | 140CRP81100 |
FNC160A-C20 | MVI69E-MBS | 3500/50 133434-01 | AS-B805-016 |
NR1SW-16T65DT | 2150-AGA | 3500/42 140471-01 | 170INT11003 |
NP1X1611-RI | PS69-DPM | 125680-01 | 140DDM39000 |
NJ-JM | MVI71-ADM | 330180-51-00 | 416NHM30032 |
NC1X6406 | MVI69-MNET | 136188-02 | MC-4/11/03/400 |
NP1AXH4DG-MR | MVI56-HART | 125388-01 125388-01H | 140CPS51100 |
The G122-202A1 Servoamplifier Card by Moog is a differential amplifier with a PID control section designed to drive electro-hydraulic servovalves in closed-loop control systems. It can also be used in applications requiring a current or voltage output proportional to a command signal or the difference between command and feedback signals.
Key Specifications:
Power Supply:
±15 VDC stabilized (25 mA each)
±24 VDC (valve + relay current)
Input Voltage Range:
Pins 3, 7: ±10 VDC
Pin 9: 0 to 120 VDC
Output Capability:
Max current: ±100 mA
Max voltage: ±10 V
Output Ranges:
Selectable with R34: 10, 20, 50, and 100 mA
Proportional Gain:
Adjustable from 5 to 200 mA/V
Linearity:
±3% of full scale
Frequency Response:
-3 dB at frequencies > 800 Hz with inductive load (1 Henry)
Dither:
Amplitude: 0 to 40% valve drive
Frequency: 25 to 300 Hz
External Controlled Relay:
Consumption: 8 mA @ 24 VDC
Contact rating: 1 A/125 VDC, 30 W max.
Dimensions:
3U x 7HP, Euro card format (100 x 160 mm)
Ramp Rate:
0.5 V/s to 20 V/s
Inverter Accuracy:
±1% of applied signal
4-20 mA Converter Accuracy:
±1% of full scale
FGU130B | NB2W90R-11 | NP1AY02-MR |
NB2W56R | CTHMIMOD-00 | NP1AXH8VG-MR |
FTU612A | NP1AXH8V-MR | NP1AXH4DG-MR |
NC1X6406 | FNC160A-C20 | NR1TW-16T65DT |
NP1F-MM1 | NP1X1611-RI | NR1DY-16T05DT |
NP1W1606T | NP1Y16T10P2 | NR1SW-16T65DT |
Description
IEC Standards testing procedures require that the mechanical durability test be carried out without current flowing in the main circuit, with the rated voltage applied to the coil and for at least as many on-off operation cycles as specified for the corresponding intermittent duty class as shown in the table on page 5. The mechanical life of the contactor is inversely proportional to the third or fourth power of the operating voltage. Therefore, if the control circuit voltage is 10% higher than the coil’s rated voltage, the mechanical durability will be reduced by half. An increase in control circuit voltage will harm the operating mechanism, core and shading coil. The results of the mechanical durability test for SC series contactors are given in the table below. The electrical durability test must be carried out for the number of operation cycles specified for the corresponding intermittent duty class shown in the table on page 5, and under the circuit conditions of the corresponding utilization category as defined in the table on page 4. Contact wear is caused by arcing that occurs between contacts when the current is interrupted. The amount of contact wear is directly proportional to approximately the second power of the interrupted current value. Therefore, when a contactor is used for inching or plugging operations, the expected service life of the contacts will be much less than if used for normal operations.
More Products
Fuji | Prosoft | Bently Nevada | Schneider |
NP1W1606T | MVI69L-MBS | 1900/65A | 490NRP25300 |
NP1F-MM1 | MVI46-MBP | 3500/65-01-01 | 140AII33010 |
FTU612A | MVI69-MCM | 3500/42 138700-01 | 140XTS00200 |
FGU130B | MVI56E-GSC | 330180-91-05 | 140CRP81100 |
FNC160A-C20 | MVI69E-MBS | 3500/50 133434-01 | AS-B805-016 |
NR1SW-16T65DT | 2150-AGA | 3500/42 140471-01 | 170INT11003 |
NP1X1611-RI | PS69-DPM | 125680-01 | 140DDM39000 |
NJ-JM | MVI71-ADM | 330180-51-00 | 416NHM30032 |
NC1X6406 | MVI69-MNET | 136188-02 | MC-4/11/03/400 |
NP1AXH4DG-MR | MVI56-HART | 125388-01 125388-01H | 140CPS51100 |